Sign In | Join Free | My himfr.com
Home > Radar Level Sensor >

Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Buy cheap Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration from wholesalers
     
    Buy cheap Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration from wholesalers
    • Buy cheap Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration from wholesalers

    Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Ask Lasest Price
    Brand Name : Atech sensor
    Model Number : PL806
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 pcs month
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Products non contact radar oil level sensor transmitter range configuration manufacturer

    Radar level sensors are typically housed in a single assembly, combining the transmitter and receiver antenna in one device.

    The two main types of radar level sensors in use are Air-to-Air Radar (TAR) and Guided Wave Radar (GWR).

    Airborne radar level sensors are the most commonly used type because they are non-contact and easier to install. The emitted magnetic waves fan out from the sensor until they hit the surface of the liquid and are reflected back. The main disadvantage of the TAR level sensor is that the electromagnetic pulse energy is attenuated by the longer distance and the lower dielectric process medium. TAR level measurement technology can be used in aggressive chemical applications as it does not come into contact with the fluid being measured.

    Guided wave radar types include a waveguide mounted in front of the sensor to focus microwave pulses and boost the reflected wave energy. This makes it possible to use GWR-type sensors with lower dielectric process media that would otherwise degrade the performance of TAR-type sensors.

    Radar level sensors are mounted above the liquid level on the top of the tank, or on a platform that spans the top of the open tank.

    How does radar level measurement work?

    The device operates according to the FMCW method (FMCW = Frequency Modulated Continuous Wave). Electromagnetic pulses in the GHz range are sent to the medium at different frequencies between 77 and 81 GHz. Since the transmitter is constantly changing the frequency of the transmitted signal, there is a frequency difference between the transmitted and reflected signals. Subtract the frequency of the reflected signal from the frequency of the transmitted signal at that time to obtain a low-frequency signal proportional to the horizontal distance. This signal is further processed to enable fast, reliable and highly accurate level measurement

    Speifications

    Technical Specifications
    Housing:
    Steel 316L
    Seal ring between housing and housing cover
    Silicone
    view Point window on housing
    Polycarbonate
    Ground terminal
    Stainless Steel
    Power:
    Two-wirc
    standard version
    (16~36) VDC
    Intrinsic safe version
    (21.6~26.4) VDC
    Power consumption
    max.22.5mA
    Ripple allowed
    —<100Hz
    Uss<1V
    —(<100~<100K)Hz
    Uss<10mV
    Four-wire/two
    intrinsic safe+explosion proof
    (21.6一26.4) VDC,
    -chamber
    Power consumption
    max.1VA,1W
    Cable:
    Cable entry/plug
    one cable entry of M20x1.5,one blind of M20x1.5
    Spring Connection terminal
    Application for cables with cross section of2.5m㎡
    Output:
    Output signal
    4~-20mA/HART
    Resolution
    1.6 μa
    Fault signal
    Constant current output:20.5mA; 22mA; 3.9mA
    Integration time
    0~50 seconds,adjustable
    Blind spot
    end of antenna
    Max. measurement distance
    10m
    Microwave frequency
    26GHz
    Measurement interval
    about 1 sec.(depend on parameter settings)
    Adjustment time
    about 1 sec.(depend on parameter settings)
    Resolution on display
    1mm
    Accuracy
    see the diagram below
    Temperature for storage/transport
    (-40~80)℃
    Process tempcrature (probe)
    (-40~250)℃
    Relative humidity
    <95%
    Pressure
    Max.4MPa
    Vibration proof
    mechanical vibration l0m/s3 ,(10~~150)Hz

    Applications

    ● City water supply

    ● Sewage treatment

    ● Tank level monitoringT

    ● Water-saving irrigation

    ● Circulation fluid monitoring

    Flange Non Contact Radar Oil Level Sensor Transmitter Range ConfigurationFlange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration

    Quality Flange Non Contact Radar Oil Level Sensor Transmitter Range Configuration for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Atech sensor Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)